
Description
Over 36,000 SF of Industrial warehouse space in two stand-alone buildings. Zone M2, Heavy Manufacturing, which includes highly-coveted indoor and outdoor self-storage opportunities. Over 33 parking stalls on a fully paved 3.01 acreage. Covered truck loading bays with quick access to I-15. ELECTRICAL: Amperage: 400 amperes x 3 Voltage/Phase, 480/240 volts, 4 wire, 3 Phase Power enters each building below ground to the meter boxes on the south side walls. Bldg 1 has a 400 ampere, 480 volt system to each of its west and east side buildings. These split off at the meter. There are main disconnects inside the building. Step down transformers convert the power from 480 volt to 240 / 120 volt, both three-phase and single-phase. Power to Bldg 2 building is a 400 ampere service, 3-phase with 480 volt. Bldg 2 has step down transformers to convert from 480 volt to 240 / 120 volt single and three phase. Each building has breaker panels located inside on the south walls. HEATING & AIR CONDITIONING: Heating: Gas Heat Distribution Forced Air Unit Heaters. Cooling: Evaporative coolers and split systems. Bldg 1 has 7 overhead doors and four lavatories in the warehouse and one in the office area. Bldg 2 has two overhead doors, one small lavatory which includes one toilet.
-
0BEDS
-
3.01ACRES
-
0BATHS
-
01/2 BATHS
School Ratings & Info
Description
Over 36,000 SF of Industrial warehouse space in two stand-alone buildings. Zone M2, Heavy Manufacturing, which includes highly-coveted indoor and outdoor self-storage opportunities. Over 33 parking stalls on a fully paved 3.01 acreage. Covered truck loading bays with quick access to I-15. ELECTRICAL: Amperage: 400 amperes x 3 Voltage/Phase, 480/240 volts, 4 wire, 3 Phase Power enters each building below ground to the meter boxes on the south side walls. Bldg 1 has a 400 ampere, 480 volt system to each of its west and east side buildings. These split off at the meter. There are main disconnects inside the building. Step down transformers convert the power from 480 volt to 240 / 120 volt, both three-phase and single-phase. Power to Bldg 2 building is a 400 ampere service, 3-phase with 480 volt. Bldg 2 has step down transformers to convert from 480 volt to 240 / 120 volt single and three phase. Each building has breaker panels located inside on the south walls. HEATING & AIR CONDITIONING: Heating: Gas Heat Distribution Forced Air Unit Heaters. Cooling: Evaporative coolers and split systems. Bldg 1 has 7 overhead doors and four lavatories in the warehouse and one in the office area. Bldg 2 has two overhead doors, one small lavatory which includes one toilet.
Related Properties
Based on information from the Wasatch Front Regional Multiple Listing Service, Inc. as of 2023-06-02T07:39:44.927. All data, including all measurements and calculations of area, is obtained from various sources and has not been, and will not be, verified by broker or the MLS. All information should be independently reviewed and verified for accuracy. Properties may or may not be listed by the office/agent presenting the information.The information provided is for consumers' personal, non-commercial use and may not be used for any purpose other than to identify prospective properties consumers may be interested in purchasing. Information deemed reliable but not guaranteed accurate. Buyer to verify all information.